Clock Generation
All functional modules in the MAXQ2000 are synchronized to a single system clock. This system clock can be generated from one of
five possible sources (Figure 5):
• Internal ring oscillator
• Internal high-frequency oscillator using external crystal or resonator circuit
• External high-frequency clock signal
• Internal 32kHz oscillator using external crystal or resonator circuit
• External 32kHz clock signal
The MAXQ2000 does not provide the option for an external RC relaxation oscillator circuit.
Table 1 shows the registers and bits used to control clock generation and selection. For more information, see the register descriptions
in this guide and the MAXQ Family User’s Guide.