Maxim-integrated 6613_PSU_1+1S_URT_v1_00 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Sprzęt komputerowy Maxim-integrated 6613_PSU_1+1S_URT_v1_00. Maxim Integrated 6613_PSU_1+1S_URT_v1_00 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - 6613_PSU_1+1S_URT_v1_00

USER GUIDE A Maxim Integrated Products Brand 6613_PSU_1+1S_URT_v1_00 Firmware Description Document

Strona 2

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 10 Rev. 1.0 6.3.3 Block Reads The block read command can also be used to r

Strona 3 - Table of Contents

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 11 )U<CR> Updates the default values of the MPU Data permanentl

Strona 4

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 12 Rev. 1.0 6.4 Auxiliary Commands 6.4.1 Repeat Command The repeat comman

Strona 5 - 1 Introduction

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 13 6.5 Calibration Commands Using the precision source method, the u

Strona 6 - 2 Measurement Description

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 14 Rev. 1.0 6.5.2 Atomic Calibration Commands The atomic calibration comma

Strona 7 - 4 Auto-reporting Mode

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 15 6.5.2.4 CLT Command The CLT command is used for the temperature c

Strona 8 - 6 Command Line Interface

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 16 Rev. 1.0 6.6.2 Consecutive CE Reads The host can request information fr

Strona 9 - 6.3 MPU Data Access Command

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 17 Examples: ]40$<CR> Reads CE data word at address location

Strona 10 - 6.3.5 U Command

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 18 Rev. 1.0 The commands that follow are included for reference only. 6.

Strona 11

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 19 7 MPU Measurement Outputs This section describes the measurement

Strona 12 - 6.4 Auxiliary Commands

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 Maxim cannot assume responsibility for use of any circuitry other than circuitry

Strona 13 - 6.5 Calibration Commands

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 20 Rev. 1.0 Output Location (hex) LSB Comment Example Vrms Under Voltage

Strona 14

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 21 Output Location (hex) LSB Comment Example Reserved 2F – Reserv

Strona 15 - 6.6 CE Data Access Commands

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 22 Rev. 1.0 Output Location (hex) LSB Comment Example VAs A Max 39 mW

Strona 16 - 6.6.3 CE Data Write

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 23 8 Configuration Parameter Entry 8.1 MPU Parameters Table 3 lists

Strona 17

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 24 Rev. 1.0 MPU Parameter Location (hex) LSB Default Comment Example Co

Strona 18 - 6.7 CE Control Commands

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 25 MPU Parameter Location (hex) LSB Default Comment Example Calib

Strona 19 - 7 MPU Measurement Outputs

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 26 Rev. 1.0 MPU Parameter Location (hex) LSB Default Comment Example To

Strona 20

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 27 MPU Parameter Location (hex) LSB Default Comment Example Frequ

Strona 21

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 28 Rev. 1.0 MPU Parameter Location (hex) LSB Default Comment Example Un

Strona 22

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 29 8.2 CE Parameters Table 4 lists the CE parameters configurable by

Strona 23 - 8.1 MPU Parameters

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 3 Table of Contents 1 Introduction ...

Strona 24 - 24 Rev. 1.0

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 30 Rev. 1.0 CE Parameter Location(hex) LSB Default Comment Example WRATE

Strona 25 - Rev. 1.0 25

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 31 9 Address Content Summary Table 5: MPU Output Summary Chart

Strona 26 - 26 Rev. 1.0

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 32 Rev. 1.0 Table 6: MPU Input Summary Chart Voltage A0 Vmax Current A1 Im

Strona 27 - Rev. 1.0 27

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 33 Voltage D4 SAG Voltage Alarm Threshold D5 Min Voltage Alarm Thre

Strona 28 - 28 Rev. 1.0

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 34 Rev. 1.0 10 Digital IOs DIO17 is a dedicated SAG status pin that is set

Strona 29 - 8.2 CE Parameters

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 35 Document Revision History Version Date History 1.0 10/29/2010

Strona 30 - 30 Rev. 1.0

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 4 Rev. 1.0 Tables Table 1: Measurement Equations Definitions ...

Strona 31 - 9 Address Content Summary

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 5 1 Introduction This document describes the 6613_PSU_1+1S_URT_v1_00

Strona 32 - 32 Rev. 1.0

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 6 Rev. 1.0 2 Measurement Description 2.1 Basic Measurement Equations Th

Strona 33

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 7 3 Serial Communication The serial communication with the 78M6613

Strona 34 - 11 Contact Information

6613_PSU_1+1S_URT_V1_00 Firmware Description Document UG_6613_040 8 Rev. 1.0 6 Command Line Interface The 6613_PSU_1+1S_URT_v1_00 firmware i

Strona 35 - Document Revision History

UG_6613_ 040 6613_PSU_1+1S_URT_V1_00 Firmware Description Document Rev. 1.0 9 6.3 MPU Data Access Command All the measurement calculations are s

Komentarze do niniejszej Instrukcji