Maxim-integrated Secure Microcontroller Instrukcja Użytkownika Strona 112

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 111
Secure Microcontroller User’s Guide
112 of 187
Figure 13-1. Timer/Counter Mode 0 and 1 Operation
13.4 Mode 2
The selection of Mode 2 configures an 8-bit timer/counter with automatic reload of a value preset by
software. Figure 13-2 illustrates a functional block diagram of this operational mode. When Timer 0 is
used in Mode 2, TL0 is incremented as each count is received. When the value of 0FFH (all 1s) is
reached, TF0 will be set on the next count and the reload value held in TH0 will be transferred into TL0.
TH0 remains unchanged until it is modified by the application software.
Timer 1 operates in an identical fashion when it is set for operation in Mode 2.
Przeglądanie stron 111
1 2 ... 107 108 109 110 111 112 113 114 115 116 117 ... 186 187

Komentarze do niniejszej Instrukcji

Brak uwag