2.8.2 Measure Command
The measure command is used to initiate or terminate a monitoring session. A monitoring session can
be for line voltage or line current. Both measuring entity (voltage and current) can be active currently.
Syntax (Stop)
FXOCTL:NN> measure <voltage|current> stop
Where: NN Show current active channel ID.
Syntax (Start)
FXOCTL:NN> measure <voltage|current> start <XX> <YY>
Where: XX Sample time interval (in ms).
YY Average Sample count (1 to 20).
NN Shows the current active channel ID.
The following is a log of the measuring commands.
Figure 13: Measure Command Logging Session
FXOCTL:00> measure voltage start 100 10
LINE_STATE(0)
HookState: OnHook, Entity: Voltage, Row: 0, Event: 1000
FXOCTL:00> measure voltage stop
Start voltage measurement
session with 100ms interval
and 10 average sample counts.
Stop voltage
measurement session.
Event triggered for voltage
matches IET row 0, on-hook
state, with event =1000.