73M1822/73M1922 Control Module User Guide UG_1x22_053
80 Rev. 1.0
7.14.3 M1X22_MEASURE_START_STOP_t
Description
This structure is used by the M1X22_MEASURE_START and M1X22_MEASURE_STOP IOCTLs to start and
stop the current or voltage measurement.
Prototype
typedef struct
{
M1X22_MEASURE_ENTITY entity;
unsigned int sample_time;
unsigned int average_sample_count;
}
M1X22_MEASURE_START_t;
Parameters
Data Type Name Description
M1X22_MEASURE_ENTITY
entity
Measuring entity current or voltage.
unsigned int
sample_time
Interval between two samplings in
milliseconds (not applicable for the
M1X22_MEASURE_STOP
IOCTL).
unsigned int
average_sample_count
Sample count for average calculation (not
applicable for the M1X22_MEASURE_STOP
IOCTL.